- Low cost glass without coatings.
- Optimises light transmission and reduces cooling loads.
- Low external and internal reflectance.
- Can be combined with Low E glass in insulating glass units for enhanced performance.
SuperTones™
Solar control single glazing
The SuperTones™ range consists of three colour options: SuperGreen, SuperGrey and SuperBlue, providing great solar control with deeper tints.
When compared to VFloat™ and VLam™ toned glass, the SuperTones™ range provide significant improvements in solar performance.
The deeper colours still allow you to enjoy natural views from your interior spaces and are maintained with low exterior reflectance.

Technical Specifications
Features & Benefits
Sectors
- Residential
- Commercial
Applications
- Windows
- Doors
- Overhead Glazing
Considerations
Installation
- We recommend that all SuperTones™ be specified and supplied as a heat strengthened or toughened glass in all situations.
How to Specify
- Available in SuperGreen, SuperGrey and SuperBlue.
- Select from: Annealed, heat strengthened, toughened, toughened heat soaked or insulated glass unit.
Standard Stock Sizes
Product Name | Thickness | Stock Size |
SuperTones™ SuperGrey | 6mm | 5180mm x 3302mm |
SuperTones™ SuperGreen | 4mm | 3660mm x 2440mm |
SuperTones™ SuperGreen | 6mm | 5100mm x 3210mm |
SuperTones™ SuperBlue | 6mm | 5180mm x 3302mm |
SuperTones™ SuperBlue | 10mm | 3302mm x 2438mm |
Note: Subject to further processing requirements. Standard stock sizes do not reflect actual available stock, please consult Viridian.
Performance Data
Product Name | Nominal Thickness | VLT (%) | U Value | SHGC | Selectivity |
SuperTones™ SuperGrey | 6 | 9 | 5.80 | 0.36 | 0.25 |
SuperTones™ SuperGreen | 6 | 67 | 5.80 | 0.53 | 1.26 |
SuperTones™ SuperBlue | 6 | 53 | 5.80 | 0.52 | 1.02 |
SuperTones™ SuperBlue | 10 | 41 | 5.70 | 0.45 | 0.91 |
All performance data is determined using LBL window 7 software. NFRC 100 – 2010 conditions have been used.
Glass surfaces are counted from the exterior to the interior of the building.
Refer to Viridian Performance Data for more values.